ABSCHRIFTEnglish

How Control-IQ Technology Works on the t:slim X2 Insulin Pump

3m 49s619 Wörter101 segmentsEnglish

VOLLSTÄNDIGE ABSCHRIFT

0:00

[Music]

0:00

Welcome. We're excited to show you how

0:03

easy control can be using the TSL X2

0:05

insulin pump with Control IQ technology

0:08

from Tandem Diabetes Care. This video

0:10

explains how Control IQ technology works

0:13

during usual day-to-day activities when

0:15

you aren't using the sleep or exercise

0:17

activity settings. To learn more about

0:19

how to use the sleep and exercise

0:21

activity settings, please watch our

0:22

other videos.

0:24

The goal of Control IQ technology is to

0:26

minimize the burden of managing your

0:28

diabetes by automatically adjusting

0:30

insulin delivery based on readings from

0:32

your continuous glucose monitor or CGM.

0:37

Using readings from the Dexcom G6 CGM,

0:40

Control IQ technology predicts what your

0:42

glucose will be in 30 minutes and

0:44

adjusts insulin delivery accordingly.

0:48

Treatment values are the CGM values that

0:50

trigger control IQ technology to act in

0:52

order to help increase time spent in the

0:54

target range of 3.9 to 10 millles per

0:57

liter.

1:00

When your glucose is predicted to be

1:01

between 6.25 millles per liter and 8.9

1:05

millles per liter 30 minutes in the

1:07

future, your pump will deliver insulin

1:09

at the rate determined by your active

1:11

personal profile.

1:13

During this time, you will see a gray

1:15

diamond icon on the home screen, and the

1:17

pump status icon will be a black B and a

1:19

light blue square.

1:21

[Music]

1:22

When your glucose is predicted to be at

1:24

or below 6.25 millles per liter, 30

1:28

minutes in the future, Control IQ

1:30

technology will begin to decrease

1:31

insulin delivery from your active

1:33

personal profile rate to help to keep

1:35

your glucose within the target range.

1:39

While this is happening, the lower half

1:40

of the diamond icon will become orange

1:43

and the pump status icon will also be

1:45

orange.

1:50

When Control IQ technology predicts that

1:52

your glucose will be below 3.9 millles

1:55

per liter 30 minutes in the future,

1:56

basil insulin delivery will be stopped.

1:59

Bolus deliveries will continue,

2:01

including any active extended bololis

2:03

currently underway. You will also be

2:05

able to start a new bolus even though

2:06

basil delivery has been stopped. When

2:09

Control IQ technology has stopped your

2:11

basil insulin delivery, the lower half

2:13

of the diamond will become red and the

2:15

pump status icon will be a red zero.

2:17

Additionally, you will see a red shaded

2:20

area on the CGM trend graph which lets

2:22

you know that basil insulin was stopped

2:23

during that time. Basil insulin delivery

2:27

will resume once your glucose is

2:29

predicted to be above 3.9 millles per

2:31

liter 30 minutes in the future.

2:35

When Control IQ technology predicts that

2:37

your glucose will be above 8.9 millmer

2:40

moles per liter 30 minutes in the

2:41

future, basil insulin delivery will be

2:44

increased.

2:46

During this time, the upper half of the

2:48

diamond icon will be blue and the pump

2:50

status icon will be a white B and a dark

2:52

blue square.

2:54

This icon is different from a personal

2:56

profile rate, which is a black B and a

2:58

light blue square.

3:01

When control IQ technology predicts that

3:03

your glucose value will be at or above

3:05

10 millm moles per liter 30 minutes in

3:07

the future. And when control IQ

3:10

technology is either increasing insulin

3:12

delivery or delivering the max basil

3:14

rate, the pump will deliver an automatic

3:16

correction bolus to help return you to

3:18

the target range.

3:20

While Control IQ technology is

3:22

delivering an automatic correction

3:24

bolus, you will see the icon of a white

3:26

droplet in a blue square.

3:29

Also note that when Control IQ

3:30

technology is delivering an automatic

3:32

correction bololis, you will see a

3:34

Control IQ bolis displayed at the bottom

3:36

of the screen. Thanks for watching this

3:39

video. We hope you enjoy seeing how easy

3:41

control can be with the T-Slim X2

3:43

insulin pump with Control IQ technology.

MEHR FREISCHALTEN

Melden Sie sich kostenlos an, um Premium-Funktionen zu nutzen

INTERAKTIVER VIEWER

Sehen Sie sich das Video mit synchronisierten Untertiteln, anpassbarer Überlagerung und voller Wiedergabesteuerung an.

KOSTENLOS ANMELDEN ZUM FREISCHALTEN

KI-ZUSAMMENFASSUNG

Erhalten Sie eine sofortige KI-generierte Zusammenfassung des Videoinhalts, der wichtigsten Punkte und Erkenntnisse.

KOSTENLOS ANMELDEN ZUM FREISCHALTEN

ÜBERSETZEN

Übersetzen Sie das Transkript mit einem Klick in über 100 Sprachen. Download in jedem Format.

KOSTENLOS ANMELDEN ZUM FREISCHALTEN

MIND MAP

Visualisieren Sie das Transkript als interaktive Mind Map. Verstehen Sie die Struktur auf einen Blick.

KOSTENLOS ANMELDEN ZUM FREISCHALTEN

CHAT MIT TRANSKRIPT

Stellen Sie Fragen zum Videoinhalt. Erhalten Sie Antworten von der KI direkt aus dem Transkript.

KOSTENLOS ANMELDEN ZUM FREISCHALTEN

HOLEN SIE MEHR AUS IHREN TRANSKRIPTEN HERAUS

Melden Sie sich kostenlos an und schalten Sie interaktiven Viewer, KI-Zusammenfassungen, Übersetzungen, Mind Maps und mehr frei. Keine Kreditkarte erforderlich.

    How Control-I… - Vollständiges Transkript | YouTubeTranscript.dev